ST3160212A不认盘恢复数据成功案例

浏览: 发布时间:2019/3/10 10:05:37

          ST3160212A不认盘恢复成功案例


客户:童先生

日期:2019.1.13

硬盘型号:ST3160212A   SN:5LS4029R    FW:3.AAE      

故障现象:硬盘通电不认盘。

解决方案:收到硬盘后据恢复工具PC-3000 UDMA Express上,通电检测发现,终端信息如下:

Interface task reset
1024k x 16 SDRAM
TONKA2 - 1_Disk    M-31   12-07-05 09:13
Head Mask FFFF - Switch to full int.
              Spin Ready
(P)PATA Reset
DiskAccess ReadSector EC=47 at ffffffff.00.0002
DiskAccess ReadSector EC=47 at ffffffff.00.0002

Read Ver Retrys
DiskAccess ReadSector EC=47 at ffffffff.00.0002

Read Ver Retrys
DiskAccess ReadSector EC=43 at ffffffff.00.0002

Read Ver Retrys
DiskAccess ReadSector EC=47 at ffffffff.00.0002

Read Ver Retrys
DiskAccess ReadSector EC=47 at ffffffff.00.0002

Read Ver Failure!
DiskAccess ReadSector EC=43 at ffffffff.00.022b
Failed sys sect. write
DiskAccess ReadSector EC=47 at ffffffff.00.0080
DiskAccess ReadSector EC=43 at ffffffff.00.0080
Unable To Load Overlay 01|000A

T>

这是希捷老盘常见的一种故障,有些是固件区有坏道引起,我们使用PC3000 UDMA的虚拟功能,虚拟加载后,硬盘正常认盘,DE镜像,成功恢复客户里面多年的照片和视频数据!